Xporter: FAQs for Schools

Summary

Frequently asked questions for Xporter and Xporter on Demand.

Answer

Scope

  • Common queries related to troubleshooting Xporter and Xporter on Demand.
  • If there is a problem with the data you are seeing in your 3rd party application(s), please ask your tech contact/network manager to first make the relevant checks according to this guide.
  • If there is still an issue, please ask your technical contact to get in touch with us directly.

Server Migration

  • If your school’s MIS or Xporter Server has been migrated, please follow the steps in this guide: How To: Migrate Xporter (Not Hosted).
  • If you have a Hosted Xporter setup, please get in touch with us.
  • For assistance with server migrations, we require at least 2 days’ notice. Please get in touch with us.

Xporter Server Checks - Missing/Incorrect Data

  • If there is missing or incorrect data in your 3rd party application, please run the basic checks below.
  • .NET Framework needs to be up to date.
    • The minimum recommended requirement is 4.6.2.
    • Ensure 3.5 Service Pack 1 is also installed.
    • Run our Support Tool to check what versions you have, if you are unsure.
  • Check Groupcall URLs are opened for port 80 and port 443 for any filtering or firewalls.
  • See our server pre-requisites guide in full: Best Practice: Xporter Pre-requisites.
  • Check Xporter is installed correctly.
    • Locate the Xporter Management Console from your Desktop or Start Menu.
    • If you are unable to locate Xporter on your MIS server, or a client server, get in touch.
    • If you have recently completed a server migration but didn’t move Xporter, read our guide for further instructions: How To: Migrate Xporter (Not Hosted).
  • Check all Groupcall Services are running.
    • Open your Xporter Management Console.
    • Click the Services tab from the left panel.
    • Locate Groupcall Xporter and check that it is currently Running.

  • Restart Groupcall Xporter.
    • Open your Xporter Management Console > click Services from the panel on the left.
    • Locate the Groupcall Xporter service > right-click > Restart.
    • If you see any errors when trying to restart, get in touch and provide us with details on the error you are seeing.

​​​​​​​

Proxy Issues – Run as User

  • Sometimes you may have trouble updating Xporter or connecting to the Xporter cloud services to deliver data if your network uses an authenticated proxy server (sometime these are transparent).
  • Log into Windows as an account with admin privileges.
  • Open the Xporter Management Console > Services section, or the Windows Services app.
  • Find the 3 Groupcall services:
    • Groupcall Xporter
    • Groupcall Emerge Service
    • Groupcall Sims Server (will only see this if your MIS is SIMS)
  • For each service, right click > Properties > Log On (repeat for all Groupcall services).
  • The service(s) usually run as the Local System Account.
  • If you are experiencing authentication issues connecting to the Internet, click This account: > enter the log on details for a Windows account with Internet access privileges. This account must also have Local Administrator rights to operate properly.
  • Stop and Restart the services if the Log On details have been changed.

Proxy Issues – Check Settings

  • Open the Xporter Management Console > click Misc in the left panel.
  • In the centre panel > click on the Proxy Server (<Server>:<Port>)setting.
  • In the right panel > click on Modify Setting.
  • Enter your proxy address, including port number if applicable. This can be either a domain:port or IP Address:Port.
    • Example formats - note, not HTTP:// on the settings:
    • proxy.myschool.local:8080
    • 10.0.0.20:8080
  • Click Submit.

MIS checks – No current data in SIMS

If you are not seeing any (current) data, please make all the below MIS checks.

  1. Open the Xporter Management Console.
  2. Click on Passwords in the left panel.
  3. In the centre panel, click on the SIMS.net (Default) Login setting.
  4. In the right panel, click on Modify Password.
  5. Enter the username and password for the SIMS user you want Xporter to use.
    • Note: We recommend having a user set up specifically for this purpose and named groupcall.
  6. Click Submit.
  7. Open SIMS and locate the user with which Xporter is configured.
  8. Check that the user has the following 5 permissions (unmodified):
    • Assessment Coordinator
    • Personnel Officer
    • School Administrator
    • Senior Management Team
    • Third Party Reporting
  9. On the same machine on which Xporter is installed, check that you can log into SIMS with the username and password entered into Xporter.

MIS checks – No current data in other MIS

If you use another MIS, please click on the correct link below to check your MIS integration has been setup correctly:

If you are aware of any changes to your MIS, get in touch with us detailing the change and we will be able to assist.

Authorising Data Sharing (Xporter on Demand only)

  • Have you completed the data sharing authorisation with the third-party application?
  • Have you selected the correct sharing mode when authorising an app?
    • For example, choosing Exclude All will mean no data is available to your app unless you manually select the data you want to share. Read our guide for further instructions: How To: Change your Data Sharing Mode.

​​​​​​​

MIS checks – Missing/Incorrect Data in SIMS

If some data is not correct I.e. a missing student, class etc. Please try the actions below before getting in touch.

  1. Run Database Diagnostics in SIMS.
  2. Run Validate Memberships in SIMS.
  3. Xporter will run the data collection jobs again overnight.
  4. For Xporter on Demand you can click Refresh my Data in your School Portal to trigger a refresh of your data.

Both processes will help to resolve many auto-fixable issues in SIMS. If you are unable to run either procedure, please contact Capita Support for assistance.

MIS checks – Missing/Incorrect Data in Other MIS

  • Please ensure that the missing data I.e. student, class, staff member has been correctly entered in your MIS. This includes checking the data is marked as current and available or sharing with third parties such as Groupcall (e.g. start date is current and end date has not been entered or is in the future).
  • Check that Xporter has the correct access to your MIS as per the guides hyperlinked in the section above: MIS checks – No current data in other MIS.

How to Raise a Support Case

  • To help us ensure your request is dealt with in the most efficient way possible to get in touch with our Support Team is through the Contact Support page (click the button on the right).
    • Note: Remember to provide us with all of the below to ensure we can efficiently deal with your request.
  • In the Description field, please include the following:
    • School’s DfE number
    • A summary of the issue, including steps you have taken so far
    • A copy of the error you are seeing, and where you are seeing it
    • Any alternative contact details I.e. a direct number/ another IT technician’s info that we would need to speak to
    • Your school’s MIS e.g. SIMS, Bromcom, Arbor etc
    • If your DfE number has changed, ensure to mention this, along with your new DfE number.